[Kopisha] China I-Online ups Room Networking Room Three Phase rack rack tower 1 ~ 30KVA
Inkcazo
Uphawu: Banatton
Indawo yemvelaphi: China
Uhlobo: UPS kwi-intanethi
Inombolo yomzekelo: BNT900-RT 1 ~ 30KVA
Bonisa: I-LED
Isigaba: IsiGaba esinye/esiThathu
I-Waveform: i-sine wave ecocekileyo
Ixesha lokutshintshela: 0ms
Umthamo: 1KVA -30KVA
Ukhuseleko: i-short-circuit, over voltages, ukubuyisela umva ukhuseleko loxhulumaniso
OEM / ODM: Ewe
Ubunakho bokubonelela: I-10000 Iqhekeza / amaqhekeza ngenyanga
Ukupakishwa: Ibhokisi yebhokisi yebhokisi okanye njengoko ucelile
Iimbonakalo
Akukho ndawo yokunciphisa xa kuziwa ekuqinisekiseni ukuthembeka kunye nokhuseleko lwezixhobo ezibalulekileyo ze-IT.Apha kulapho iinkqubo ze-UPS ezixhonywe kwi-rack zingena khona.I-Rack-mounted UPS (amandla angenakuphazamiseka) yenzelwe ukunika amandla okugcina amandla ngexesha lokuphela kombane okanye ukuguquguquka, ukuqinisekisa ukusebenza okungaphazamisekiyo kweeseva, ukutshintsha kunye nezixhobo zokugcina.
Enye yeempawu eziphambili kwishishini le-UPS yerack yaziwa ngetekhnoloji yokuguqula kabini.Oku kuthetha ukuba amandla angenayo e-AC ahlala eguqulelwa kumandla e-DC aze abuyele kumandla e-AC, ebonelela ngemveliso ecocekileyo, ezinzileyo yesixhobo sakho.Oku kuqinisekisa ukuba izixhobo zakho zifumana amandla azinzileyo ngaphandle kokuguquguquka kombane wokufaka okanye ukuphindaphindwa.
Ukongeza, le nkqubo ye-UPS ifakwe kwi-rack isebenzisa itekhnoloji yokuguqula kabini i-intanethi.Oku kuthetha ukuba unikezelo lwamandla luhlala lubekwe esweni kwaye lulungiswa ngokuzenzekelayo ukuze kupheliswe naziphi na izikhewu, ii-surges okanye i-voltage dips kubonelelo lombane.Oku kubaluleke ngakumbi kwihlabathi lanamhlanje ledijithali, apho kwanokucima kombane okufutshane kunokubangela ilahleko yedatha ebiza kakhulu okanye umonakalo wesixhobo.
Ukuphucula ngakumbi ukusebenza kwayo, le nkqubo ye-UPS ifakwe kwi-rack ifaka itekhnoloji ye-DSP.I-DSP, okanye i-digital signal processing, ivumela ukuchaneka okukhulu kunye namaxesha okuphendula ngokukhawuleza xa kuhlolwa kwaye kulungiswe ukunikezelwa kwamandla.Oku kuqinisekisa ukuba isixhobo sakho sihlala sikhuselekile, nakwezona ndawo zinemfuno kakhulu.
Le nkqubo ye-UPS efakwe kwi-rack ine-output power factor ye-0.9 kwaye inokusingatha imithwalo eyahlukeneyo yezixhobo.Oku kuthetha ukuba unokudibanisa izixhobo ezininzi kwi-UPS ngaphandle kokuchaphazela ukusebenza kwayo.Nokuba unamaseva anamandla aphezulu okanye uthotho logcino oluninzi, le nkqubo ye-UPS inyuswe ngerakhi ingahlangabezana neemfuno zakho.
Olunye uphawu olwahlulayo lwale nkqubo ye-UPS efakwe kwi-rack luluhlu olubanzi lwamandla ombane.Yamkela amandla ombane ukusuka kwi-110 ukuya kwi-300 VAC, iyenza ihambelane nemithombo eyahlukeneyo yamandla.Oku kuguquguquka kuqinisekisa ukuba kunokusetyenziswa kwiindawo ezahlukeneyo okanye kwiindawo ezingqongileyo ngaphandle kwesidingo sezixhobo ezongezelelweyo okanye ukuguqulwa.
Ukongeza, le nkqubo ye-UPS ixhonywe kwi-rack ifaka itekhnoloji yolungiso lwamandla asebenzayo.Isixhobo salo samandla yi-0.99, ukwandisa ukusebenza kakuhle kwamandla okufaka, ukunciphisa inkunkuma yamandla kunye nokugcina iindleko zombane.Oku kubaluleke ngakumbi kumashishini abeka phambili ukuzinza kunye nokusebenza kakuhle kwamandla.
Ukongeza kwiimpawu zayo zobugcisa obuphezulu, le nkqubo ye-UPS efakwe kwi-rack inika uluhlu lwemisebenzi ephathekayo.Ine-50Hz/60Hz imowudi yokuguqulwa kwamaxesha kwaye inokuziqhelanisa neegridi zamandla ahlukeneyo okanye imigangatho yamazwe ngamazwe.Ikwabonisa i-Emergency Power Off (EPO) inqaku lokhuseleko olongezelelweyo ngexesha likaxakeka okanye umsebenzi wokulondoloza.
Ukuhambelana neejenereyitha yenye inzuzo yale nkqubo ye-rack UPS.Iyakwazi ukutshintshela ngaphandle komthungo phakathi kwee-mains kunye nombane wejenereyitha ngaphandle kokuphazamiseka, ukubonelela ngokubonelela ngombane okuqhubekayo ngexesha lokuphela kombane okude okanye xa amandla amakhulu engathembekanga.Olu phawu luluncedo kakhulu kumashishini abekwe kwiindawo ezithanda ukucima kombane.
Ukubeka iliso kunye nokulawula okulula, le nkqubo ye-UPS efakwe kwi-rack iza kunye ne-SNMP / USB / RS-232 iinketho zonxibelelwano.Olu nxibelelwano lukuvumela ukuba uqhagamshele i-UPS kwinethiwekhi okanye kwikhompyuter kwaye ufikelele kulwazi lwexesha lokwenyani malunga namandla, ubume bebhetri, kunye nempilo yenkqubo.Oku kwenza kube lula ukucombulula iingxaki kwaye kukunceda ukuba uqonde ukusebenza kwesiseko sakho se-IT.
Ukuqinisekisa ukusebenza kakuhle kwebhetri kunye nexesha elide lokulondoloza, le nkqubo ye-UPS efakwe kwi-rack ivumela ukuba inani leebhetri lihlengahlengiswe.Unokwenza inani leeyunithi ngokweemfuno zakho ezithile, kukunika ukuguquguquka kokulinganisela ixesha lokusebenza kunye neendleko zenkqubo.
Kumashishini aneemfuno eziphezulu zokuthembeka, i-N+X parallel redundancy configuration inokukhethwa.Eli nqaku livumela iiyunithi ezininzi ze-UPS ukuba zidityaniswe ngokuhambelanayo ukuze zibonelele ngokuphinda-phinda xa kukho ukungaphumeleli kwe-UPS.Oku kuqinisekisa ukuba iinkqubo zakho ezibalulekileyo zihlala zikhuselwe, nokuba kukho ukusilela kwehardware.
Okokugqibela kodwa okuncinci, le nkqubo ye-UPS ifakwe kwi-rack inika ukusebenza kokuqala okubandayo.Oku kuthetha ukuba inokuthi inikwe amandla ngaphandle kwawo nawaphi na amandla angundoqo, ixhomekeke kuphela kwibhetri yayo yangaphakathi.Oku kuluncedo ngakumbi ngexesha lofakelo lokuqala okanye xa kucinywe umbane ngokupheleleyo, kukuvumela ukuba ukhawuleze nangokukhuselekileyo ubuyisele inkqubo yakho kwi-intanethi.
Isishwankathelo, xa kuziwa ekukhuseleni iziseko zakho ze-IT ezibalulekileyo, inkqubo ye-rack ye-UPS eneempawu eziphambili kunye nezakhono kufuneka.Ngobuchwephesha bayo bokwenene obuphindwe kabini, iteknoloji ye-intanethi ye-intanethi ye-double-conversion kunye nobuchwepheshe be-DSP, le nkqubo ye-UPS efakwe kwi-rack inika ukuthembeka okuphezulu, ukusebenza kakuhle kunye nokusebenza.Uluhlu lwayo lwamandla ombane olubanzi, ulungiso lwamandla asebenzayo, kunye nokuhambelana neejeneretha kukunika ukuguquguquka ukuziqhelanisa neemeko ezahlukeneyo zamandla.Ukongeza, izinto ezisebenzayo ezifana ne-SNMP/USB/RS-232 yonxibelelwano, ukubalwa kwebhetri okuhlengahlengiswayo, kunye nokuzikhethela kwe-N + X parallel redundancy iqinisekisa ulawulo olulula kunye nokulinganisa.Ngenqaku lokuqala elibandayo, unokuqiniseka ukuba inkqubo yakho iya kuhlala isebenza, nokuba imeko ithini.Ke musa ukuyekelela ekukhuseleni izixhobo zakho ezibalulekileyo-tyala imali kwi-rack-mounted UPS inkqubo enikezela ukusebenza okungenakulinganiswa kunye noxolo lwengqondo.
Umboniso weMveliso
1. Iinkonzo ze-OEM&ODM zamkelekile.
2. Iiarhente ezininzi ezibambiseneyo zokuthunyelwa ngolwandle okanye ngomoya.
3. Iwaranti ye-1year, ukuba yingxaki esemgangathweni, siya kubonelela ngeengxenye simahla.
Usetyenziso
Iziko lokusetyenzwa kwedatha, Inkqubo yokusingatha, iiseva zeKhompyutha, ezoNyango, iTrafikhi, uMbane, iIT, iShishini kunye namanye amashishini.
Umgca weMveliso weFactory
Ukupakishwa
UMZEKELO | I-BNT9010S(H)-R-31 | I-BNT9015S(H)-R-31 | I-BNT9020S(H)-R-31 | |
ISIGABA | 3-isigaba kwi / 1-isigaba ngaphandle | |||
UBUKHONO | 10000 VA/9000 W | 15000 VA/13500 W | 20000 VA / 18000 W | |
Igalelo | ||||
Amandla oMbane | 3 x 400 VAC (3Ph+N) | |||
Uluhlu lwamandla ombane | I-190-520 VAC (isigaba se-3) kwi-50% yomthwalo;I-305-478 VAC (isigaba se-3) kwi-100% umthwalo | |||
Uluhlu lokuphindaphinda | 46 ~ 54 Hz okanye 56 ~ 64Hz | |||
Amandla Factor | ≥ 0.99 @ 100% Umthwalo | |||
THDi | < 6% @ 100% Umthwalo | |||
IPHUMO | ||||
Umbane ophumayo | 208/220/230/240VAC | |||
Ulawulo lwe-AC Voltage (Imo yeBatt.) | ± 1% | |||
Uluhlu lokuphindaphinda (uluhlu oludityanisiweyo) | 46 ~ 54Hz okanye 56 ~ 64Hz | |||
Uluhlu lokuphindaphinda (iNdlela yeBatt.) | 50 Hz ± 0.1 Hz okanye 60 Hz ± 0.1 Hz | |||
Ireyishini yeCrest yangoku | 3:01 | |||
Ukuphazamiseka kweHarmonic | ≤ 2% THD (Umthwalo woMda);≤ 5 % THD (Umthwalo ongekho mgca) | |||
Ukudluliselwa | Imo ye-AC ukuya kwiBat.Imowudi | Unothi | ||
Ixesha | Isiguquli kwi-Bypass | Unothi | ||
Imo yeWave (Imo yeBatt.) | I-Sinewave ecocekileyo | |||
UKUSEBENZA | ||||
Imowudi ye-AC | 90.50% | 91% | ||
Imo ye-ECO | 96% | 96% | ||
Imo yebhetri | 87% | 88% | ||
IBHETRI | ||||
Uhlobo Lwebhetri | 12 V / 9 Ah | |||
Umzekelo oMgangatho | Amanani | 20 (18 – 20 iipcs* ezilungelelanisiweyo) | 20 iipcs x 2 imitya (18 – 20 iipcs* adjustable) | |
Ixesha lokuTshajwa kwakhona | Iiyure ze-9 zibuyela kwi-90% umthamo | |||
Ukutshaja okwangoku (ubuninzi.) | 1A | 2A | ||
Ukutshaja iVoltage | 273 VDC ± 1% (ngokusekelwe kumanani ebhetri kwi-20 pcs) | |||
Imodeli yexesha elide | Uhlobo Lwebhetri | Kuxhomekeke kumthamo weebhetri zangaphandle | ||
Amanani | ||||
Ukutshaja okwangoku (ubuninzi.) | 4A | |||
Ukutshaja iVoltage | 273 VDC ± 1% (ngokusekelwe kumanani ebhetri kwi-20 pcs) | |||
IZALATHISI | ||||
Umboniso weLCD | Ubume be-UPS, inqanaba loMlayisho, inqanaba lebhetri, igalelo lombane / imveliso, isibali-xesha sokukhupha, kunye neemeko zeFault | |||
I-ALARM | ||||
Imo yebhetri | Isandi rhoqo kwimizuzwana emi-4 | |||
Ibhetri elisezantsi | Isandi rhoqo ngesekondi | |||
Ukulayisha ngaphezulu | Isandi kabini ngomzuzwana ngamnye | |||
Impazamo | Isandi esiqhubekayo | |||
EMZIMBENI | ||||
Umzekelo oMgangatho | Ubungakanani, D x W x H (mm) | Iyunithi ye-UPS: 668 x 438 x 133 [3U] | Iyunithi ye-UPS: 668 x 438 x 266 [6U] | |
Ibhetri ipakethi: 580 x 438 x 133 [3U] | Ibhetri ipakethi: 580 x 438 x 133 [3U] x 2PCS | |||
Ubunzima obuNina (kg) | Iyunithi ye-UPS: 22 | Iyunithi ye-UPS: 45 | ||
Ibhetri ipakethi: 63 | Ipakethi yebhetri: 63 x 2 iipcs | |||
Imodeli yexesha elide | Ubungakanani, D x W x H (mm) | 668 x 438 x 133 [3U] | 668 x 438 x 266 [6U] | |
Ubunzima obuNina (kg) | 22 | 45 | ||
IMEKO | ||||
Ukufuma okuSebenzayo | 0-95 % RH @ 0- 40°C (Ayi-condensing) | |||
Inqanaba Lengxolo | Ngaphantsi kwe-60dB @ 1 Meter | Ngaphantsi kwe-65dB @ 1 Meter | ||
ULAWULO | ||||
Smart RS-232 / USB | Ixhasa iWindows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux kunye neMAC | |||
Ukhetho lweSNMP | Ulawulo lwamandla ukusuka kumphathi weSNMP kunye nesikhangeli sewebhu |